Outdoor Expulsion Drop-out Type Distribution Fuse Cutout 11KV
Application: Protection device for protecting power system from over-load and short-circuit failure.
Ratings: 11kV-36kV.
Standards: IEC 600282-2
Features:
1, High over-current protection capability, high breaking current.
2, High industrial frequency withstands voltage, and mechanical strength, etc.
3, High quality on strict testing.
Technical Data:
Rated voltage: 11kV to 66kV.
Rated current: Up to 200A.
Note: For detail, please refer to the catalogue.
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/a731ecb1ff0324de3fce8a94856be7d1.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/cce61dfc79b15f145666e2150ac73ad8.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/d7d84ecf3f5d72746f51e560a94f2c72.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/cfeb00dfdd69ead821854d7b71d8f213.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/d0ec92301de4b5223a5fbd26fc54efbc.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/20c3ca64a787dfbf95de16023145c221.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/b11cab8fd0bc00932ed00b1e81a8dc7b.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/48be5ab51eec27f70ccd41e33901bb36.webp)
Application: Protection device for protecting power system from over-load and short-circuit failure.
Ratings: 11kV-36kV.
Standards: IEC 600282-2
Features:
1, High over-current protection capability, high breaking current.
2, High industrial frequency withstands voltage, and mechanical strength, etc.
3, High quality on strict testing.
Technical Data:
Rated voltage: 11kV to 66kV.
Rated current: Up to 200A.
Note: For detail, please refer to the catalogue.
Rated Voltage (kV) | Rated current (A) | Breaking current (A) | Impulse voltage (BIL) | Power-frequency withstand voltage (kV) | Leakage distance (MM) |
11 | 100 | 10000 | 125 | 45 | 320 |
11 | 200 | 12000 | 125 | 45 | 320 |
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/a731ecb1ff0324de3fce8a94856be7d1.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/cce61dfc79b15f145666e2150ac73ad8.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/d7d84ecf3f5d72746f51e560a94f2c72.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/cfeb00dfdd69ead821854d7b71d8f213.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/d0ec92301de4b5223a5fbd26fc54efbc.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/20c3ca64a787dfbf95de16023145c221.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/b11cab8fd0bc00932ed00b1e81a8dc7b.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/48be5ab51eec27f70ccd41e33901bb36.webp)
![Outdoor Expulsion Drop-out Type Distribution Fuse Cutout (with two insulator)](https://img2.grofrom.com/aporcelaininsulators/c4ac7b4fb2d6747f184dfc2213077482.webp)